■ Flexibility facilitating conductor clamping even in narrow space
■ AC current measurable max. 3000A
■ True RMS■ Data hold, Max/Min value hold
■ BacklightSampling rate : approx. 2 times / sec.
تشاهد 1–24 من94 النتائج
CURRENT, VOLTAGE, Type K CALIBRATOR
Model : CC-423
* CURRENT CALIBRATOR :
1. Current source: 0 to 24 mA
2. Current measurement : 0 to 24 mA.
3. Power ( 12V ) and current measurement of two wires loop.
4. Resolution : 0.01 mA.
* VOLTAGE CALIBRATOR :
DC mV source: -199.9 mV to +199.9 mV.
* Type K CALIBRATOR :
1. Type K thermocouple calibrator.
2. Type K Thermocouple thermometer.
3. -199 oC to 1230 oC , -325 oF to 2246 oF.
4. oC/oF, Resolution : 0.1 degree.
* Power :
1.5V ( UM-3/AA ) battery x 6 PCs or DC 9V adapter in.
* Housing case with tripod fix nut structure.
* Optional type K Temp. probes :
TP-01, TP-02A , TP-03, TP-04, TP-05.
ا
DC V | 6.000/60.00/600.0V (auto range) ±0.5%rdg ±3dgt |
---|---|
DC mV | 600.0mV ±1.5%rdg ±3dgt |
DC Clamp Sensor | 60.00/200.0A (auto range) ±1.5%rdg ±3dgt + Sensor accuracy |
AC V | 6.000/60.00/600.0V (auto range) ±1.0%rdg ±3dgt [40 – 500Hz] |
AC mV | 600.0mV ±2.0%rdg ±3dgt [40 – 500Hz] |
AC Clamp Sensor | 60.00/200.0A (auto range) ±2.0%rdg ±3dgt + Sensor accuracy [40 – 500Hz] |
DC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt |
AC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt[45 – 500Hz] |
Ω | 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ (auto range) ±0.5%rdg ±4dgt (600Ω), ±0.5%rdg ±2dgt (6/60/600kΩ/6MΩ) ±1.5%rdg ±3dgt (40MΩ) |
Continuity buzzer | 600Ω (Buzzer sounds below 90Ω) |
Diode test | Open-loop voltage: < 3.0V |
Capacitance | 60.00/600.0nF/6.000/60.00/600.0/1000µF ±2.0%rdg ±5dgt (60/600nF) ±5.0%rdg ±5dgt (6/60/600/1000µF) |
Frequency | ACV 99.99/999.9Hz/9.999/99.99kHz ±0.1%rdg ±3dgt ACA 99.99/999.9Hz/9.999kHz ±0.1%rdg ±3dgt |
DUTY | 10.0 – 90.0% ±1.0%rdg ±3dgt [50/60Hz] |
Applicable standards | IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS) |
Power source | R03 (1.5V) × 2 |
Dimensions | 155(L) × 75(W) × 40(D)mm |
Weight | 250g Approx. (including batteries) |
Included Accessories | Wing-type holder, Flat-type holder, 7066A (Test leads), 8919 (Ceramic fuse [10A/600V]) × 1 (included), 9097 (Carrying case), R03 × 2, Instruction manua |
ACA | 199.9/600A | ±(2%+5)(50~60Hz) | 0.1A |
±(2.9%+5)(60~400Hz) | |||
ACV | 199.9/600V | ±(1.5%+5)(50~400Hz) | 0.1V |
Resistance | 199.9Ω | ±(1.0%+8) | 0.1Ω |
Continuity | Buzzer sounds at less than approx. 100Ω Open voltage : approx.1.0V | ||
Bandwidth | 50~400Hz | ||
Display | 1999 | ||
Clamp diameter/ | 25mm / 10 x 30mm |
AC A | 400A/2000A (0 – 1000A) ±1.5%rdg±2dgt [50/60Hz] ±3%rdg±4dgt [40 – 500Hz] ±5%rdg±4dgt [500Hz – 1kHz] 2000A (1001 – 2000A) ±3%rdg±2dgt [50/60Hz] |
---|---|
DC A | 400/2000A ±1.5%rdg±2dgt |
AC V | 400/750V ±1.5%rdg±2dgt [50/60Hz] ±1.5%rdg±4dgt [40Hz – 1kHz] |
DC V | 400/1000V ±1%rdg±2dgt |
Ω | 400/4000Ω ±1.5%rdg±2dgt |
Continuity buzzer | buzzer sounds below 50±35Ω |
Conductor size | Ø55mm max. |
Frequency response | 40Hz – 1kHz |
Output | Recorder : DC400mV against AC/DC400A DC200mV against AC/DC2000A |
Safety Standard | IEC 61010-1 CAT IV 600V , CAT III 1000V IEC 61010-031 IEC 61010-2-032 |
Power source | R6 (AA) (1.5V) × 2 |
Dimensions | 250(L) × 105(W) × 49(D)mm |
Weight | 530g approx. |
Included Accessories | 7107A (Test leads) 9094 (Carrying Case) R6 (AA) × 2 Instruction Manual |
DC voltage (V) | 400mV/4V/40V/400V/1000V | ±(0.5%+5) |
AC voltage (V) | 4V/40V/400V/750V | ±(0.8%+3) |
DC current (A) | 40uA/400uA/4mA/40mA/400mA/10A | ±(0.8%+3) |
AC current (A) | 40mA/400mA/10A | ±(1%+2) |
Resistance (Ω) | 400Ω/4000Ω/40kΩ/400kΩ/4MΩ/200MΩ | ±(0.8%+2) |
Capacitance (F) | 4nF/40nf/400nF/4uF/40uF/400uF/4mF/10mF | ±(4%+5) |
Features | ||
Display count | 4000 | |
Transistor hFE | √ | |
Diode | √ | |
Frequency response | 40Hz~400Hz | √ |
Range selection | Manual | |
Continuity test | √ | |
Data hold | √ | |
Backlight | √ | |
Low battery indication | √ | |
Auto power off | √ | |
General Characteristics | ||
Power | 1.5V battery (R03)×2 | |
Display | 56.5mm x 36mm | |
Product color | Red and grey | |
Product net weight | 330g | |
Product size | 175mm x 83mm x 53mm | |
Standard accessories | Test leads |
Brand : Fluke
Model Number : 319
Resolution up to 0.01A and 0.1 V
Measures AC/DC current to 1000 A (319)
Measures AC/DC volts to 600 V
Resistance measurement to 4000 Ω
Continuity for quick checking of shorts
Auto-shut-off maximizes battery life so the meter works when you need it
Digital Display : 6000 count resolution
Low Battery Indication : Displays a signal when the batteries are below their required voltage
Power Source : Three AAA IEC LR03 batteries
Voltage LED Steps (AC/D):
– 12 V (between 0 to 12 V LED will illuminate)
– 24 V (between 19 V +/- 2 V LED will illuminate)
– 50 V (between 48 V +/- 6 V LED will illuminate)
– 120 V (between 110 V +/- 20 V LED will illuminate)
– 230 V (between 200 V +/- 20 V LED will illuminate)
– 400 V (between 340 V +/- 30 V LED will illuminate)
– 690 V (between 520 V +/- 30 V LED will illuminate)
Continuity test: Range 0 to 100 kOhm. The continuity LED will illuminate and buzzer will sound
Phase Rotation Test: 50Hz to 60Hz
Range Selection: Automatic
Polarity Detection: Positive & Negative
Low Battery Display: Short circuit two leads, LED and beeper do not on that means the battery is low
Torch: Yes
Single Lead (L2) Voltage Detection: It is intended only as a quick check. 100V to 690V, 50Hz to 400Hz
Short Circuit Detection: Yes
GENERAL CHARACTERISTICS:
Power: 2x 1.5 V battery (AAA)
LCD display (AC/DC): 24V to 690V (+/- 3%+5)
Product Net Weight: 210 g
Product size: 275 x 51 x 30 mm
AC Current | 10AAC |
AC Voltage | 1000V AC |
Capacitance | 100µF |
DC Current Measurement | 10A DC |
DC Voltage | 1000V DC |
Resistance | >40MΩ |
AC Current Resolution | 0.1µA ac |
AC Voltage Resolution | 1mV ac |
Battery Type | AA |
Best AC Current Accuracy | ±1.8% + 5 Digits |
Best AC Voltage Accuracy | ±1.2% + 7 Digits |
Best Capacitance Measurement Accuracy | ±5% + 10 Digits |
Best DC Current Accuracy | ±1.4% + 3 Digits |
Best DC Voltage Accuracy | ±0.5% + 2 Digits |
Best Resistance Measurement Accuracy | ±1.2% + 5 Digits |
Capacitance Measurement Resolution | 10pF |
DC Current Measurement Resolution | 0.1µA dc |
DC Voltage Measurement Resolution | 0.1mV dc |
Dimension | 44 x 82 x 166mm |
Display Type | LCD |
Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance |
Height | 166mm |
Length | 44mm |
Maximum Frequency | 400Hz |
Model Number p | CD771 |
Resistance Measurement Resolution | 100mΩ |
Safety Category | CAT II 1000 V, CAT III 600 V |
Safety Category Level | CAT II, CAT III |
Safety Category Voltage | 600 V, 1000 V |
True RMS | Yes |
Weight | 360g |