■ Flexibility facilitating conductor clamping even in narrow space
■ AC current measurable max. 3000A
■ True RMS■ Data hold, Max/Min value hold
■ BacklightSampling rate : approx. 2 times / sec.
تشاهد 1–24 من94 النتائج
C millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on 250 Ω detects opens or shorts of 500 μs or longer. |
|
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500Hz) |
Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.5% + 3 20 A overload for 30-seconds max |
|
DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 20 A overload for 30-seconds max |
|
Hz (V or A input)2 | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.01 Hz 9.999 kHz / 0.001 kHz 50.00 kHz / 0.01 kHz |
Accuracy | 0.1% + 2 |
AC Current 40A/600A ±(2.5%+5)
DC Current 40A/600A ±(2.5%+5)
AC Voltage 4V/40V/400V/600V ±(1%+5)
DC Voltage 400mV/4V/40V/400V/600V ±(0.8%+1)
Resistance 400Ohm/4KOhm/40KOhm/400KOhm/4MOhm/40MOhm ±(1%+2)
Capacitance4nF/40nF/400nF/4µF/40µF/100µF±(4%+3)
Frequency
10Hz ~ 10MHz ±(0.5%+3)
10MHz Reference only
Temperature -40 °C ~ 1000°C ±(2.5%+3)
Features
Display Count 3999
Auto Range
Jaw Capacity 28mm
Diode
Auto Power Off
Continuity Buzzer
Low Battery Indication
Data Hold
MAX Mode
Setup
Input Impedance for DCV Around 10MOhm
General Characteristic
Power 9V Battery(6F22)
LCD Size 35.6X 18mm
Product Color Red and Grey
Product Net Weight 260g
Product Size 208mm X 76mm X30 mm
Standard Accessories Battery, Test Lead,Carrying Bag,Point Contact Temperature Probe, Gift Box, English Manual
ACA | 199.9/600A | ±(2%+5)(50~60Hz) | 0.1A |
±(2.9%+5)(60~400Hz) | |||
ACV | 199.9/600V | ±(1.5%+5)(50~400Hz) | 0.1V |
Resistance | 199.9Ω | ±(1.0%+8) | 0.1Ω |
Continuity | Buzzer sounds at less than approx. 100Ω Open voltage : approx.1.0V | ||
Bandwidth | 50~400Hz | ||
Display | 1999 | ||
Clamp diameter/ | 25mm / 10 x 30mm |
CURRENT, VOLTAGE, Type K CALIBRATOR
Model : CC-423
* CURRENT CALIBRATOR :
1. Current source: 0 to 24 mA
2. Current measurement : 0 to 24 mA.
3. Power ( 12V ) and current measurement of two wires loop.
4. Resolution : 0.01 mA.
* VOLTAGE CALIBRATOR :
DC mV source: -199.9 mV to +199.9 mV.
* Type K CALIBRATOR :
1. Type K thermocouple calibrator.
2. Type K Thermocouple thermometer.
3. -199 oC to 1230 oC , -325 oF to 2246 oF.
4. oC/oF, Resolution : 0.1 degree.
* Power :
1.5V ( UM-3/AA ) battery x 6 PCs or DC 9V adapter in.
* Housing case with tripod fix nut structure.
* Optional type K Temp. probes :
TP-01, TP-02A , TP-03, TP-04, TP-05.
Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
Product Details
LOG AND TREND MEASUREMENTS TO PINPOINT INTERMITTENT FAULTS
TRANSMIT RESULTS WIRELESSLY VIA FLUKE CONNECT MEASUREMENTS APP
CREATE AND SEND REPORTS RIGHT FROM THE FIELD
STAY SAFELY AWAY FROM THE ARC FLASH ZONE THROUGH BLUETOOTH CONNECTIVITY TO APPLE AND ANDROID DEVICES
IFLEX FLEXIBLE CURRENT PROBE EXPANDS THE MEASUREMENT RANGE TO 2500 A AC; PROVIDES ACCESS TO LARGE CONDUCTORS IN TIGHT SPACES (INCLUDED)
INTEGRATED VFD LOW PASS FILTER FOR ACCURATE MOTOR DRIVE MEASUREMENTS
1000 A AC AND DC CURRENT MEASUREMENT
2500 A AC CURRENT MEASUREMENT WITH IFLEX FLEXIBLE CURRENT PROBE
1000 V AC AND DC VOLTAGE MEASUREMENT
INCLUDES: SOFT CARRYING CASE
Brand : Fluke
Model Number : 319
Resolution up to 0.01A and 0.1 V
Measures AC/DC current to 1000 A (319)
Measures AC/DC volts to 600 V
Resistance measurement to 4000 Ω
Continuity for quick checking of shorts
Auto-shut-off maximizes battery life so the meter works when you need it
Digital Display : 6000 count resolution
Low Battery Indication : Displays a signal when the batteries are below their required voltage
Power Source : Three AAA IEC LR03 batteries
ا
DC V | 6.000/60.00/600.0V (auto range) ±0.5%rdg ±3dgt |
---|---|
DC mV | 600.0mV ±1.5%rdg ±3dgt |
DC Clamp Sensor | 60.00/200.0A (auto range) ±1.5%rdg ±3dgt + Sensor accuracy |
AC V | 6.000/60.00/600.0V (auto range) ±1.0%rdg ±3dgt [40 – 500Hz] |
AC mV | 600.0mV ±2.0%rdg ±3dgt [40 – 500Hz] |
AC Clamp Sensor | 60.00/200.0A (auto range) ±2.0%rdg ±3dgt + Sensor accuracy [40 – 500Hz] |
DC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt |
AC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt[45 – 500Hz] |
Ω | 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ (auto range) ±0.5%rdg ±4dgt (600Ω), ±0.5%rdg ±2dgt (6/60/600kΩ/6MΩ) ±1.5%rdg ±3dgt (40MΩ) |
Continuity buzzer | 600Ω (Buzzer sounds below 90Ω) |
Diode test | Open-loop voltage: < 3.0V |
Capacitance | 60.00/600.0nF/6.000/60.00/600.0/1000µF ±2.0%rdg ±5dgt (60/600nF) ±5.0%rdg ±5dgt (6/60/600/1000µF) |
Frequency | ACV 99.99/999.9Hz/9.999/99.99kHz ±0.1%rdg ±3dgt ACA 99.99/999.9Hz/9.999kHz ±0.1%rdg ±3dgt |
DUTY | 10.0 – 90.0% ±1.0%rdg ±3dgt [50/60Hz] |
Applicable standards | IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS) |
Power source | R03 (1.5V) × 2 |
Dimensions | 155(L) × 75(W) × 40(D)mm |
Weight | 250g Approx. (including batteries) |
Included Accessories | Wing-type holder, Flat-type holder, 7066A (Test leads), 8919 (Ceramic fuse [10A/600V]) × 1 (included), 9097 (Carrying case), R03 × 2, Instruction manua |