■ Flexibility facilitating conductor clamping even in narrow space
■ AC current measurable max. 3000A
■ True RMS■ Data hold, Max/Min value hold
■ BacklightSampling rate : approx. 2 times / sec.
تشاهد 1–24 من94 النتائج
Brand : Fluke
Model Number : 319
Resolution up to 0.01A and 0.1 V
Measures AC/DC current to 1000 A (319)
Measures AC/DC volts to 600 V
Resistance measurement to 4000 Ω
Continuity for quick checking of shorts
Auto-shut-off maximizes battery life so the meter works when you need it
Digital Display : 6000 count resolution
Low Battery Indication : Displays a signal when the batteries are below their required voltage
Power Source : Three AAA IEC LR03 batteries
DC Voltage: 400mV / 4V / 40V / 400V / 600V
– best accuracy: +/- (0.8%+1)
AC Voltage: 4V / 40V / 400V / 600V
– best accuracy: +/- (1%+5)
DC Current: 40A / 400A
– best accuracy: +/- (2%+3)
AC Current: 40A / 400A
– best accuracy: +/- (2.5%+5)
Resistance: 400 Ohm / 4 kOhm / 40 kOhm / 400 kOhm / 4 MOhm / 40 MOhm
-best accuracy: +/- (1%+2)
Frequency: 10Hz – 1MHz
– best accuracy: +/- (0.1%+3)
Duty cycle: 0.1% ~ 99.9%
Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
Product Details
LOG AND TREND MEASUREMENTS TO PINPOINT INTERMITTENT FAULTS
TRANSMIT RESULTS WIRELESSLY VIA FLUKE CONNECT MEASUREMENTS APP
CREATE AND SEND REPORTS RIGHT FROM THE FIELD
STAY SAFELY AWAY FROM THE ARC FLASH ZONE THROUGH BLUETOOTH CONNECTIVITY TO APPLE AND ANDROID DEVICES
IFLEX FLEXIBLE CURRENT PROBE EXPANDS THE MEASUREMENT RANGE TO 2500 A AC; PROVIDES ACCESS TO LARGE CONDUCTORS IN TIGHT SPACES (INCLUDED)
INTEGRATED VFD LOW PASS FILTER FOR ACCURATE MOTOR DRIVE MEASUREMENTS
1000 A AC AND DC CURRENT MEASUREMENT
2500 A AC CURRENT MEASUREMENT WITH IFLEX FLEXIBLE CURRENT PROBE
1000 V AC AND DC VOLTAGE MEASUREMENT
INCLUDES: SOFT CARRYING CASE
AC Current 40A/600A ±(2.5%+5)
DC Current 40A/600A ±(2.5%+5)
AC Voltage 4V/40V/400V/600V ±(1%+5)
DC Voltage 400mV/4V/40V/400V/600V ±(0.8%+1)
Resistance 400Ohm/4KOhm/40KOhm/400KOhm/4MOhm/40MOhm ±(1%+2)
Capacitance4nF/40nF/400nF/4µF/40µF/100µF±(4%+3)
Frequency
10Hz ~ 10MHz ±(0.5%+3)
10MHz Reference only
Temperature -40 °C ~ 1000°C ±(2.5%+3)
Features
Display Count 3999
Auto Range
Jaw Capacity 28mm
Diode
Auto Power Off
Continuity Buzzer
Low Battery Indication
Data Hold
MAX Mode
Setup
Input Impedance for DCV Around 10MOhm
General Characteristic
Power 9V Battery(6F22)
LCD Size 35.6X 18mm
Product Color Red and Grey
Product Net Weight 260g
Product Size 208mm X 76mm X30 mm
Standard Accessories Battery, Test Lead,Carrying Bag,Point Contact Temperature Probe, Gift Box, English Manual
AC A | 0 – 600.0/1000A ±1.5%rdg±5dgt (50/60Hz) ±3.0%rdg±5dgt (40 – 400Hz) |
---|---|
DC A | 0 – 600.0/1000A ±1.5%rdg±5dgt |
AC V | 6/60/600V Auto Ranging ±1.3%rdg±4dgt (50/60Hz) ±3.0%rdg±5dgt (40 – 400Hz) |
DC V | 600m/6/60/600V Auto Ranging ±1.0%rdg±3dgt |
Ω | 600/6k/60k/600k/6M/60MΩ (Auto Ranging) ±1%rdg±5dgt (600 – 6M) / ±5%rdg±8dgt (60M) |
Continuity buzzer | Buzzer Sounds at 100Ω |
Frequency/DUTY | 10/100/1k/10kHz (Auto Ranging) / 0.1 – 99.9% |
Conductor size | Ø40mm |
ا
DC V | 6.000/60.00/600.0V (auto range) ±0.5%rdg ±3dgt |
---|---|
DC mV | 600.0mV ±1.5%rdg ±3dgt |
DC Clamp Sensor | 60.00/200.0A (auto range) ±1.5%rdg ±3dgt + Sensor accuracy |
AC V | 6.000/60.00/600.0V (auto range) ±1.0%rdg ±3dgt [40 – 500Hz] |
AC mV | 600.0mV ±2.0%rdg ±3dgt [40 – 500Hz] |
AC Clamp Sensor | 60.00/200.0A (auto range) ±2.0%rdg ±3dgt + Sensor accuracy [40 – 500Hz] |
DC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt |
AC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt[45 – 500Hz] |
Ω | 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ (auto range) ±0.5%rdg ±4dgt (600Ω), ±0.5%rdg ±2dgt (6/60/600kΩ/6MΩ) ±1.5%rdg ±3dgt (40MΩ) |
Continuity buzzer | 600Ω (Buzzer sounds below 90Ω) |
Diode test | Open-loop voltage: < 3.0V |
Capacitance | 60.00/600.0nF/6.000/60.00/600.0/1000µF ±2.0%rdg ±5dgt (60/600nF) ±5.0%rdg ±5dgt (6/60/600/1000µF) |
Frequency | ACV 99.99/999.9Hz/9.999/99.99kHz ±0.1%rdg ±3dgt ACA 99.99/999.9Hz/9.999kHz ±0.1%rdg ±3dgt |
DUTY | 10.0 – 90.0% ±1.0%rdg ±3dgt [50/60Hz] |
Applicable standards | IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS) |
Power source | R03 (1.5V) × 2 |
Dimensions | 155(L) × 75(W) × 40(D)mm |
Weight | 250g Approx. (including batteries) |
Included Accessories | Wing-type holder, Flat-type holder, 7066A (Test leads), 8919 (Ceramic fuse [10A/600V]) × 1 (included), 9097 (Carrying case), R03 × 2, Instruction manua |
DC voltage (V) | 400mV/4V/40V/400V/1000V | ±(0.5%+5) |
AC voltage (V) | 4V/40V/400V/750V | ±(0.8%+3) |
DC current (A) | 40uA/400uA/4mA/40mA/400mA/10A | ±(0.8%+3) |
AC current (A) | 40mA/400mA/10A | ±(1%+2) |
Resistance (Ω) | 400Ω/4000Ω/40kΩ/400kΩ/4MΩ/200MΩ | ±(0.8%+2) |
Capacitance (F) | 4nF/40nf/400nF/4uF/40uF/400uF/4mF/10mF | ±(4%+5) |
Features | ||
Display count | 4000 | |
Transistor hFE | √ | |
Diode | √ | |
Frequency response | 40Hz~400Hz | √ |
Range selection | Manual | |
Continuity test | √ | |
Data hold | √ | |
Backlight | √ | |
Low battery indication | √ | |
Auto power off | √ | |
General Characteristics | ||
Power | 1.5V battery (R03)×2 | |
Display | 56.5mm x 36mm | |
Product color | Red and grey | |
Product net weight | 330g | |
Product size | 175mm x 83mm x 53mm | |
Standard accessories | Test leads |