■ Flexibility facilitating conductor clamping even in narrow space
■ AC current measurable max. 3000A
■ True RMS■ Data hold, Max/Min value hold
■ BacklightSampling rate : approx. 2 times / sec.
تشاهد 1–24 من94 النتائج
Brand : Fluke
Model Number : 319
Resolution up to 0.01A and 0.1 V
Measures AC/DC current to 1000 A (319)
Measures AC/DC volts to 600 V
Resistance measurement to 4000 Ω
Continuity for quick checking of shorts
Auto-shut-off maximizes battery life so the meter works when you need it
Digital Display : 6000 count resolution
Low Battery Indication : Displays a signal when the batteries are below their required voltage
Power Source : Three AAA IEC LR03 batteries
AC Current 40A/600A ±(2.5%+5)
DC Current 40A/600A ±(2.5%+5)
AC Voltage 4V/40V/400V/600V ±(1%+5)
DC Voltage 400mV/4V/40V/400V/600V ±(0.8%+1)
Resistance 400Ohm/4KOhm/40KOhm/400KOhm/4MOhm/40MOhm ±(1%+2)
Capacitance4nF/40nF/400nF/4µF/40µF/100µF±(4%+3)
Frequency
10Hz ~ 10MHz ±(0.5%+3)
10MHz Reference only
Temperature -40 °C ~ 1000°C ±(2.5%+3)
Features
Display Count 3999
Auto Range
Jaw Capacity 28mm
Diode
Auto Power Off
Continuity Buzzer
Low Battery Indication
Data Hold
MAX Mode
Setup
Input Impedance for DCV Around 10MOhm
General Characteristic
Power 9V Battery(6F22)
LCD Size 35.6X 18mm
Product Color Red and Grey
Product Net Weight 260g
Product Size 208mm X 76mm X30 mm
Standard Accessories Battery, Test Lead,Carrying Bag,Point Contact Temperature Probe, Gift Box, English Manual
Voltage LED Steps (AC/D):
– 12 V (between 0 to 12 V LED will illuminate)
– 24 V (between 19 V +/- 2 V LED will illuminate)
– 50 V (between 48 V +/- 6 V LED will illuminate)
– 120 V (between 110 V +/- 20 V LED will illuminate)
– 230 V (between 200 V +/- 20 V LED will illuminate)
– 400 V (between 340 V +/- 30 V LED will illuminate)
– 690 V (between 520 V +/- 30 V LED will illuminate)
Continuity test: Range 0 to 100 kOhm. The continuity LED will illuminate and buzzer will sound
Phase Rotation Test: 50Hz to 60Hz
Range Selection: Automatic
Polarity Detection: Positive & Negative
Low Battery Display: Short circuit two leads, LED and beeper do not on that means the battery is low
Torch: Yes
Single Lead (L2) Voltage Detection: It is intended only as a quick check. 100V to 690V, 50Hz to 400Hz
Short Circuit Detection: Yes
GENERAL CHARACTERISTICS:
Power: 2x 1.5 V battery (AAA)
LCD display (AC/DC): 24V to 690V (+/- 3%+5)
Product Net Weight: 210 g
Product size: 275 x 51 x 30 mm
AC A | 400A/2000A (0 – 1000A) ±1.5%rdg±2dgt [50/60Hz] ±3%rdg±4dgt [40 – 500Hz] ±5%rdg±4dgt [500Hz – 1kHz] 2000A (1001 – 2000A) ±3%rdg±2dgt [50/60Hz] |
---|---|
DC A | 400/2000A ±1.5%rdg±2dgt |
AC V | 400/750V ±1.5%rdg±2dgt [50/60Hz] ±1.5%rdg±4dgt [40Hz – 1kHz] |
DC V | 400/1000V ±1%rdg±2dgt |
Ω | 400/4000Ω ±1.5%rdg±2dgt |
Continuity buzzer | buzzer sounds below 50±35Ω |
Conductor size | Ø55mm max. |
Frequency response | 40Hz – 1kHz |
Output | Recorder : DC400mV against AC/DC400A DC200mV against AC/DC2000A |
Safety Standard | IEC 61010-1 CAT IV 600V , CAT III 1000V IEC 61010-031 IEC 61010-2-032 |
Power source | R6 (AA) (1.5V) × 2 |
Dimensions | 250(L) × 105(W) × 49(D)mm |
Weight | 530g approx. |
Included Accessories | 7107A (Test leads) 9094 (Carrying Case) R6 (AA) × 2 Instruction Manual |
ا
DC V | 6.000/60.00/600.0V (auto range) ±0.5%rdg ±3dgt |
---|---|
DC mV | 600.0mV ±1.5%rdg ±3dgt |
DC Clamp Sensor | 60.00/200.0A (auto range) ±1.5%rdg ±3dgt + Sensor accuracy |
AC V | 6.000/60.00/600.0V (auto range) ±1.0%rdg ±3dgt [40 – 500Hz] |
AC mV | 600.0mV ±2.0%rdg ±3dgt [40 – 500Hz] |
AC Clamp Sensor | 60.00/200.0A (auto range) ±2.0%rdg ±3dgt + Sensor accuracy [40 – 500Hz] |
DC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt |
AC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt[45 – 500Hz] |
Ω | 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ (auto range) ±0.5%rdg ±4dgt (600Ω), ±0.5%rdg ±2dgt (6/60/600kΩ/6MΩ) ±1.5%rdg ±3dgt (40MΩ) |
Continuity buzzer | 600Ω (Buzzer sounds below 90Ω) |
Diode test | Open-loop voltage: < 3.0V |
Capacitance | 60.00/600.0nF/6.000/60.00/600.0/1000µF ±2.0%rdg ±5dgt (60/600nF) ±5.0%rdg ±5dgt (6/60/600/1000µF) |
Frequency | ACV 99.99/999.9Hz/9.999/99.99kHz ±0.1%rdg ±3dgt ACA 99.99/999.9Hz/9.999kHz ±0.1%rdg ±3dgt |
DUTY | 10.0 – 90.0% ±1.0%rdg ±3dgt [50/60Hz] |
Applicable standards | IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS) |
Power source | R03 (1.5V) × 2 |
Dimensions | 155(L) × 75(W) × 40(D)mm |
Weight | 250g Approx. (including batteries) |
Included Accessories | Wing-type holder, Flat-type holder, 7066A (Test leads), 8919 (Ceramic fuse [10A/600V]) × 1 (included), 9097 (Carrying case), R03 × 2, Instruction manua |
ACA | 199.9/600A | ±(2%+5)(50~60Hz) | 0.1A |
±(2.9%+5)(60~400Hz) | |||
ACV | 199.9/600V | ±(1.5%+5)(50~400Hz) | 0.1V |
Resistance | 199.9Ω | ±(1.0%+8) | 0.1Ω |
Continuity | Buzzer sounds at less than approx. 100Ω Open voltage : approx.1.0V | ||
Bandwidth | 50~400Hz | ||
Display | 1999 | ||
Clamp diameter/ | 25mm / 10 x 30mm |