voltage: 20V
Charge current: 2A
Charges 20V 2.0Ah battery in 1Hr
تشاهد 49–72 من1614 النتائج
ا
DC V | 6.000/60.00/600.0V (auto range) ±0.5%rdg ±3dgt |
---|---|
DC mV | 600.0mV ±1.5%rdg ±3dgt |
DC Clamp Sensor | 60.00/200.0A (auto range) ±1.5%rdg ±3dgt + Sensor accuracy |
AC V | 6.000/60.00/600.0V (auto range) ±1.0%rdg ±3dgt [40 – 500Hz] |
AC mV | 600.0mV ±2.0%rdg ±3dgt [40 – 500Hz] |
AC Clamp Sensor | 60.00/200.0A (auto range) ±2.0%rdg ±3dgt + Sensor accuracy [40 – 500Hz] |
DC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt |
AC A | 6.000/10.00A (auto range) ±1.5%rdg ±3dgt[45 – 500Hz] |
Ω | 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ (auto range) ±0.5%rdg ±4dgt (600Ω), ±0.5%rdg ±2dgt (6/60/600kΩ/6MΩ) ±1.5%rdg ±3dgt (40MΩ) |
Continuity buzzer | 600Ω (Buzzer sounds below 90Ω) |
Diode test | Open-loop voltage: < 3.0V |
Capacitance | 60.00/600.0nF/6.000/60.00/600.0/1000µF ±2.0%rdg ±5dgt (60/600nF) ±5.0%rdg ±5dgt (6/60/600/1000µF) |
Frequency | ACV 99.99/999.9Hz/9.999/99.99kHz ±0.1%rdg ±3dgt ACA 99.99/999.9Hz/9.999kHz ±0.1%rdg ±3dgt |
DUTY | 10.0 – 90.0% ±1.0%rdg ±3dgt [50/60Hz] |
Applicable standards | IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS) |
Power source | R03 (1.5V) × 2 |
Dimensions | 155(L) × 75(W) × 40(D)mm |
Weight | 250g Approx. (including batteries) |
Included Accessories | Wing-type holder, Flat-type holder, 7066A (Test leads), 8919 (Ceramic fuse [10A/600V]) × 1 (included), 9097 (Carrying case), R03 × 2, Instruction manua |
AC A | 400A/2000A (0 – 1000A) ±1.5%rdg±2dgt [50/60Hz] ±3%rdg±4dgt [40 – 500Hz] ±5%rdg±4dgt [500Hz – 1kHz] 2000A (1001 – 2000A) ±3%rdg±2dgt [50/60Hz] |
---|---|
DC A | 400/2000A ±1.5%rdg±2dgt |
AC V | 400/750V ±1.5%rdg±2dgt [50/60Hz] ±1.5%rdg±4dgt [40Hz – 1kHz] |
DC V | 400/1000V ±1%rdg±2dgt |
Ω | 400/4000Ω ±1.5%rdg±2dgt |
Continuity buzzer | buzzer sounds below 50±35Ω |
Conductor size | Ø55mm max. |
Frequency response | 40Hz – 1kHz |
Output | Recorder : DC400mV against AC/DC400A DC200mV against AC/DC2000A |
Safety Standard | IEC 61010-1 CAT IV 600V , CAT III 1000V IEC 61010-031 IEC 61010-2-032 |
Power source | R6 (AA) (1.5V) × 2 |
Dimensions | 250(L) × 105(W) × 49(D)mm |
Weight | 530g approx. |
Included Accessories | 7107A (Test leads) 9094 (Carrying Case) R6 (AA) × 2 Instruction Manual |
UNI-T | ||
digital multimeter | ||
AC voltage, capacitance, continuity, DC voltage, resistance | ||
LCD (3000), with a backlit | ||
4x/s | ||
3/30/300V | ||
±(1% + 3 digits) | ||
3/30/300V | ||
±(1% + 4 digits) | ||
300/3k/30k/300k/3M/30MΩ | ||
±(1% + 3 digits) | ||
3n/30n/300n/3µ/30µ/300µ/3mF | ||
±(3% + 5 digits) | ||
yes | ||
acoustic signal for R<10Ω, acoustic signal for R<70Ω | ||
182x27x20mm |